Skip to content

4.Modbus-RTU Communication Protocol Control ​

4.1 Register Address Description ​

img_9.png

The gripper defaults to the standard Modbus RTU protocol at a default baud rate is 2Mbps and the slave ID is 0x08. The currently supported function codes are: 0x03 / 0x10. In this article, data analysis is big-endian analysis.

  • 0x03: Read registers
  • 0x06: Write Single Register
  • 0x10: Write multiple registers

Read:

Addressdescription
0x0000motion state
0x0001speed(r/min)
0x0002percentage of current
0x0003current
0x0004command position
0x0006motor position
0x0008position error
0x000Fcurrent alarm code

Write:

AddressDescriptionRangeUnitFactory Setting
0x0100Enable0-1;0
0x010AMode0-2; 0:opening and closing mode 1:position mode。0
0x0303Speed0-4000r/min1000
0x0505Clip Detection Threshold30-1000.01A50
0x0506Holding Current Limit (force)10-1000.01A50
0x0508Drop Detection Threshold500-2000r/min1000
0x0601Baud Rate0: 4800 1: 9600 2: 19200 8: 921600 9: 1M 10: 1.5M 11: 2Mbps11
0x0700Position Command High0-0xFFFF-0
0x0701Position Command low0-0xFFFF-0
0x0702Position Feedback High0-0xFFFF-read-only
0x0703Position Feedback Low0-0xFFFF-read-only

motion state(0x0000)

bit1:000:stop statebit3:200:not enable
01: motion state10:enable state
10:clamping state
11: there's an error in the gripper

4.2 Read BIO Gripper Register ​

Register Function

Read Register
Request
Modbus RTU DataSlave ID (Gripper)1 Byte0x08
Function Code1 Byte0x03
Register Starting Address2 BytesAddress
Quantity of Register2 BytesN*
Modbus CRC162 BytesCRC*
Response
Modbus RTU DataSlave ID1 Byte0x08
Function Code1 Byte0x03
Byte Count1 ByteN*x2
Registers ValueN*x2 BytesValue
Modbus CRC162 BytesCRC*

N* = Quantity of Registers

Address = Register Starting Address

CRC* = Cyclic Redundancy Check

Resgister

Resgister Starting AddressRegister Value
Get Gripper status Register0x00002 BytesDisabled: 0x0000 Enabling: 0x0004 Enabling completed: 0x0008Stop status: 0x0008 Motion status: 0x0009Clipping status: 0x000A Error status: 0x000B
Get Gripper Error Register0x000F2 BytesAn error occurs: all other return values indicate an error(except 0)No error occurred: 0x0000

4.3 Write BIO Gripper Register ​

Register Function

Write Register
Request
Modbus RTU DataSlave ID (Gripper)1 Byte0x08
Function Code1 Byte0x10
Register Starting Address2 BytesAddress
Quantity of Register2 BytesN*
Byte Count1 ByteN*x2
Registers ValueN*x2 BytesValue
Modbus CRC162 BytesCRC*
Response
Modbus RTU DataSlave ID1 Byte0x08
Function Code1 Byte0x10
Register Starting Address2 BytesAddress
Quantity of Registers2 BytesN*
Modbus CRC162 BytesCRC*

N* = Quantity of Registers

Address = Register Starting Address

CRC* = Cyclic Redundancy Check

Resgister:

Resgister Starting AddressRegister Value
Enable/Disable Gripper Register0x01002 BytesEnable : 0x0001 Disable : 0x0000
Set Gripper Position Register0x07004 BytesOpen the Gripper : 0x0000 0x0082 Close the Gripper : 0x0000 0x0032
Set Gripper Speed Register0x03032 Bytes0x0000-0x0BB8 unit: r/min
Clear Error Register0x000F2 Bytes0x0000

4.4 Modbus RTU Example ​

Use Modbus RTU to control BIO Gripper G2 opening and closing, mode 1.

  1. Set the Bio Gripper G2 mode 1. Address: 0x010A. Last two digits are CRC: 6D AD, still effective after power off.
Send:08 06 11 0A 00 01 6D AD
Response:08 06 11 0A 00 01 6D AD
  1. Enable the Gripper。Address:0x0100。
Send:08 06 01 00 00 01 49 6F
Response:08 06 01 00 00 01 49 6F
  1. Open the Gripper. Position:150,Speed: 3000,Force:50。